This product is now available as part of the MSA+ program
Explore Benefits ALTAIR io™ Dock
ALTAIR io™ Dock
The io 4 Dock enables effortless calibration and bump testing which helps to improve compliance and safety. When in the io Dock, the Altair io 4 portable gas detector knows when it needs a bump test and immediately runs the appropriate test. When the ALTAIR io 4 is in the Dock, all compliance reporting is sent immediately to your MSA Grid account, helping to minimize the risks associated with manual record keeping or data file management.
Show Less
ALTAIR io™ Dock
Highlights
Videos
Specifications
Options
Approvals
Literature
Highlights
- Simultaneous testing of multiple detectors and sensor configurations
- Test bank can include up to three cylinder holders and 10 test stands with no messy calibration gas tubing
- Gas Cylinders can be RFID-enabled or manually configured
- Cylinder Holder LEDs provide Light band indication of low, empty, or expired calibration gas
- No networking required for compliance reporting to the cloud-based MSA Grid account
- The display indicates current Bank status including current cylinder expiration and pressure in PSI or Bar, while Test Stand LEDs and display indicates current test and test stand status
- The io4 Dock Leverages the ALTAIR io 4 connectivity for fast, correct test system setup with no complex user-interface
- Test Modes include:
- Bump test only
- Calibration only
- Bump test with calibration on failure of bump
- Smart Mode - Dock will perform a bump test or calibration as required by the Grid-configured gas detector settings without user intervention
Videos
Show More Videos
Show Less Videos
Specifications
Applications
Confined Space
Emergency Response
Turnarounds & Plant Maintenance
Approvals / Standards
RoHS and REACH
CE and UKCA
FCC and EU (RED) Radio compliance
Display Type
Display Technology: 3.5 inch, 320*480 (RGB) resolution with viewing angle of 85 degrees
User Interface: Large, intuitive and easy-to-read
Multi-Lingual Support: English (Additional languages will be supported in future)
Backlight: Integrated backlight for easy viewing in low-light conditions and at a distance
Markets
Construction
Fire Service
Utilities
Oil & Gas
Mining
General Industry
Mounting
Mountable using DIN EN 50 022 Rail 1m x 35mm x 7.5mm
Power Supply
Input voltage: 5V, 5A
Size
Cylinder Holder Weight: 1.34kg (2.95 lbs)
Test Stand Weight: 1.14kg (2.52 lbs)
Test Stand Dimensions: 15.5cm L x 16.4cm W x 30.3cm H (6.1” L x 6.5” W x 11.9” H)
Cylinder Holder Dimensions: 15.5cm L x 16.4 W x 30.3 H (6.1” L x 6.5” W x 11.9” H)
Durability
- Operating Temperature: 0C-40C (32F-104F)
- Rugged Design:
- No doors or closures
- Test Stand tested to over 150,000 device insertions
- Latching mechanism withstands 75lb retention force
- No connectivity required to report Bank status to cloud included cylinder gas expiration, cylinder gas pressure and test results
- Bluetooth version 4.0
- IEEE 802.11 b/g/n WLAN interface for future features
- Ethernet connectivity
- Low 0.25l/min nominal flow rate
- Integrated gas delivery system
- Standard Bump Test Time: max. 40 seconds
- Standard Calibration Time: approx. 150 seconds
- Smart: Dock will perform a bump test or calibration as required by the Grid-configured gas detector settings without user intervention. This mode allows for hands-off, intuitive operation of the Dock to help ensure device compliance. The device will perform a bump test or calibration when the Grid-configured bump test or calibration interval has elapsed.
- Bump Test Only: Dock will always perform a bump test on the inserted device, regardless of whether it needs a bump test or not. In this mode, a calibration will never be performed.
- Calibration Only: Dock will always perform a calibration on the inserted device, regardless of whether it needs a calibration or not. In this mode, a bump test will never be performed.
- Bump Test / Calibration on Bump Test Fail: Dock will first perform a bump test. If the bump test fails, it will then proceed to perform a calibration. Note that if a calibration is due on the device, it will skip the bump test and proceed directly to calibration.
Approvals
Approvals subject to change without notice and may differ based on configuration, part number and/or country. Contact Customer Service or check approval label on product for specific approval information.